The dilator insertion kit is used for preparing the cannulation of vessels for extracorporeal circuilation.The kit can be used for vascular access procedures. Typical cannulation procedure include:
-artery cannulation, such as femoral artery, axillary artery;
-vein cannulation, such as femoral vein, internal jugular vein.


| Specification | Dilator Size | Guide Wire Size | Other contents |
| D1-100-13 | 2-stage (stepped) dilator:8/10Fr、10/12Fr、12/14Fr、14/16Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-100-20 | 2-stage (stepped) dilator:8/10Fr、12/14Fr、16/18Fr、20/22Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-100-21 | 2-stage (stepped) dilator:10/12Fr、12/14Fr、14/16Fr、16/18Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-100-22 | 2-stage (stepped) dilator:10/12Fr、12/14Fr、14/16Fr、18/20Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-100-28 | 2-stage (stepped) dilator:10/12Fr、14/16Fr、18/20Fr、22/24Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-150-13 | 2-stage (stepped) dilator:8/10Fr、10/12Fr、12/14Fr、14/16Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-150-20 | 2-stage (stepped) dilator:8/10Fr、12/14Fr、16/18Fr、20/22Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-150-21 | 2-stage (stepped) dilator:10/12Fr、12/14Fr、14/16Fr、16/18Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-150-22 | 2-stage (stepped) dilator:10/12Fr、12/14Fr、14/16Fr、18/20Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D1-150-28 | 2-stage (stepped) dilator:10/12Fr、14/16Fr、18/20Fr、22/24Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-100-01 | single stage dilator:10Fr、12Fr、14Fr、16Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-100-02 | single stage dilator:12Fr、14Fr、16Fr、18Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-100-03 | single stage dilator:14Fr、16Fr、18Fr、20Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-100-04 | single stage dilator:16Fr、18Fr、20Fr、22Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-100-05 | single stage dilator:18Fr、20Fr、22Fr、24Fr | 0.035''×100CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-150-01 | single stage dilator:10Fr、12Fr、14Fr、16Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-150-02 | single stage dilator:12Fr、14Fr、16Fr、18Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-150-03 | single stage dilator:14Fr、16Fr、18Fr、20Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-150-04 | single stage dilator:16Fr、18Fr、20Fr、22Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
| D2-150-05 | single stage dilator:18Fr、20Fr、22Fr、24Fr | 0.035''×150CM | 18Ga puncture needle、11#scalpel、10ml syringe |
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Tel: 86-13861170368
WhatsApp: +86-13861170368
No. 2925, Long Cheng Av., Xinbei District, Changzhou
Changzhou Kangxin Medical Instruments Co., Ltd. is located in Changzhou, Jiangsu province. We are an enterprise specialized in the research, development and production of medical consumables, especially for cardiovascular and cardiology products.
With advanced production and testing facilities, our company has capacity to provide high quality medical equipment. The whole production process is completed in purification workshops.